CASE SERIES OF LEADLESS DEVICE IMPLANTATIONS IN A PERIPHERAL CENTER: ANALYSIS OF INDICATIONS AND OUTCOMES
Anno:
2026
Background Leadless intracardiac pacemakers have been developed to reduce complications associated with conventional cardiac implantable electronic devices (CIEDs), particularly pocket- and lead-related complications, including infections, lead dislodgement, fracture, and system-related septicemia Methods From September 2022 to December 2025, 63 leadless pacemakers were implanted in our center: 30 single-chamber devices,…
CHALLENGING PACEMAKER IMPLANT IN SINUS NODE DYSFUNCTION AND CARDIAC INVOLVEMENT IN ERDHEIM-CHESTER DISEASE: A MULTIMODALITY IMAGING GUIDED PROCEDURE
Anno:
2026
Erdheim–Chester disease (ECD) is a rare systemic non- Langerhans cells histiocytosis of unknown etiology characterized by multiorgan xanthomatous infiltration by foamy histiocytes. Cardiovascular involvement in ECD is frequent, at level of the right atrium and superior vena cava. We present the case of a 67-year-old woman with history of…
EVALUATING CORRECT S-ICD POSITIONING IN ANATOMIC ANOMALIES: WHEN TWO PROJECTIONS X-RAY ARE NOT ENOUGH.
Anno:
2026
Background Growing evidence supports omitting defibrillation testing (DFT) during subcutaneous ICD (S-ICD) implantation. The PRAETORIAN score, based on two-view chest X-ray findings, accurately predicts defibrillation efficacy, allowing clinicians to avoid discomfort and risks associated with DFT. However, certain anatomical variations may limit its applicability. Case presentation We present the…
A MIDDLE GROUND BETWEEN TRANSVENOUS AND SUBCUTANEOUS DEFIBRILLATION: EXTRAVASCULAR ICD IN A YOUNG HCM PATIENT WITH LEAD FAILURE
Anno:
2026
BACKGROUND: In hypertrophic cardiomyopathy (HCM), an implantable cardioverter-defibrillator (ICD) is a Class I recommendation according to ESC guidelines after resuscitated ventricular fibrillation. In young patients, however, decades of exposure to transvenous leads translate into a meaningful risk of lead failure, venous obstruction and infections. Subcutaneous ICDs avoid the vascular…
DUAL-CHAMBER LEADLESS PACEMAKER PACING AS A POTENTIAL STRATEGY IN ISOLATED LEFT SUPERIOR VENA CAVA
Anno:
2026
A 67-year-old man was referred for catheter ablation and permanent pacing due to symptomatic bradycardia–tachycardia form of sinus node dysfunction (SND), characterized by paroxysmal atrial fibrillation (AF), intolerance to antiarrhythmic therapy related to sinus bradycardia and chronotropic incompetence. Transthoracic echocardiography demonstrated preserved left ventricular systolic function and a markedly…
LEADLESS ATRIAL PACEMAKER WITH S-ICD IN AN HOCM PATIENT: A CASE REPORT
Anno:
2026
BACKGROUND: Managing patients who require both atrial pacing and sudden cardiac death (SCD) prevention is challenging, especially in young individuals who may face repeated device implantations. Combining a leadless atrial pacemaker with a subcutaneous defibrillator (S-ICD) can provide effective atrial pacing with preserved arrhythmic protection, minimizing infective and procedural…
FULLY INTRATHORACIC SURGICAL EV-ICD IMPLANTATION IN PATIENT WITH RETROSTERNAL HEMATOMA
Anno:
2026
Patient Presentation A 77-years old man with a recent hospitalization for a late presentation myocardial infarction was discharged with a severe compromission of the ventricular ejection fraction. During the cardiovascular rehabilitation he developed an episode of SVT with hemodynamic instability treated with RCP with rapid ROSC. Then he accessed…
ROLE OF NURSES AND ARTIFICIAL INTELLIGENCE IN REMOTE MONITORING OF INSERTABLE LOOP RECORDERS: EXPERIENCE AT ANNUNZIATA HOSPITAL, COSENZA
Anno:
2026
Background: Remote monitoring (RM) of insertable loop recorders (ILRs) generates high volumes of transmissions, often increasing clinic workload. We evaluated the impact of cloud-based AccuRhythm™ AI algorithms combined with structured nursing oversight on transmission volume and clinical workload. Methods: Retrospective analysis of 103 consecutive patients implanted with LINQ II…